Fire Rated

WS52W / AS/NZS 3013 Fire Resistant Power Cable

0.6/1kV fire resistant and low-smoke halogen-free power cable for essential services and critical electrical circuits in Australian and New Zealand projects, designed for WS52W wiring systems in accordance with AS/NZS 3013.
Fire rated cable with cable construction
Discuss This Cable →

TECHNICAL SPECIFICATION

Product NameWS52W Fire Resistant Power Cable
DesignationWS52W / AS/NZS 3013
ConstructionCopper Conductor / Mica Fire Barrier / X-HF-110 Insulation / HFS-110-TP LSZH Sheath
Core Configuration2C+E / 3C+E / 4C+E
ConductorStranded Annealed Copper
Fire BarrierMica Tape
InsulationX-HF-110 Fire Resistant Halogen-Free Compound
SheathHFS-110-TP Low Smoke Zero Halogen (LSZH) Sheath
Voltage Rating0.6/1kV
Reference StandardsAS/NZS 3013 · AS/NZS 5000.1
Optional Performance ReferenceAS/NZS 4507

Send your cable schedule for manufacturing-source matching and a project quotation. Technical and certification documents are provided for the proposed supply.

PRODUCT CONFIGURATION RANGE

CORE × SIZE CONFIGURATIONS

2 CORE + EARTH

  • 2C+E 1.5 mm² + E1.5 mm²
  • 2C+E 2.5 mm² + E2.5 mm²
  • 2C+E 4 mm² + E2.5 mm²
  • 2C+E 6 mm² + E2.5 mm²
  • 2C+E 10 mm² + E4 mm²
  • 2C+E 16 mm² + E6 mm²
  • 2C+E 25 mm² + E6 mm²
  • 2C+E 35 mm² + E10 mm²
  • 2C+E 50 mm² + E16 mm²
  • 2C+E 70 mm² + E25 mm²
  • 2C+E 95 mm² + E25 mm²

3 CORE + EARTH

  • 3C+E 1.5 mm² + E1.5 mm²
  • 3C+E 2.5 mm² + E2.5 mm²
  • 3C+E 4 mm² + E2.5 mm²
  • 3C+E 6 mm² + E2.5 mm²
  • 3C+E 10 mm² + E4 mm²
  • 3C+E 16 mm² + E6 mm²
  • 3C+E 25 mm² + E6 mm²
  • 3C+E 35 mm² + E10 mm²
  • 3C+E 50 mm² + E16 mm²
  • 3C+E 70 mm² + E25 mm²
  • 3C+E 95 mm² + E25 mm²

4 CORE + EARTH

  • 4C+E 1.5 mm² + E1.5 mm²
  • 4C+E 2.5 mm² + E2.5 mm²
  • 4C+E 4 mm² + E2.5 mm²
  • 4C+E 6 mm² + E2.5 mm²
  • 4C+E 10 mm² + E4 mm²
  • 4C+E 16 mm² + E6 mm²
  • 4C+E 25 mm² + E6 mm²
  • 4C+E 35 mm² + E10 mm²
  • 4C+E 50 mm² + E16 mm²
  • 4C+E 70 mm² + E25 mm²
  • 4C+E 95 mm² + E25 mm²

TECHNICAL REFERENCE

WHAT DOES WS52W MEAN?

WS
Wiring System
5
120-minute circuit integrity under specified fire conditions
2
Defined mechanical protection classification
W
Circuit integrity following specified water exposure

WS52W is a wiring-system classification under AS/NZS 3013. Final compliance depends on the tested cable and installation system, including supports, fixing methods and installation configuration.

RFQ / SEND SPECIFICATION

Have a WS52W Fire Resistant Cable Requirement?

Send the project location, AS/NZS 3013 requirement, cable schedule, BOQ or technical specification for review.
Request a Quote →